Latest Products

AED

Order Detail
FEATURES: 
Three-step defibrillation process
Two-button operation

Blood & Infusion Warmer (New Type, Single Channel)

Order Detail
FEATURES
High accurate, intelligent microprocessor controlled device for all medical departments:

Operation Room Equipments, Anesthesia Machine (1 Vaporizer,2 Gas)

Order Detail

Anesthesia Machine: MODEL: TR-2100


CERAMOTHERM 3000

Order Detail

Radiant Warmers CERAMOTHERM are the result of nearly 40 years of continuous development in the medical use of infrared radiation. Convenient handling and function, comfortable operation as well as a safe use are the priorities of this radiant warmer.

IUD Kit

Order Detail

No

Product List

Each in Package

1

Vaginal Retractor, 90x22

1

2

Vaginal Retractor, 100x30

1

3

Vaginal Retractor, 118x37

1

4

16cm Vaginal Retractor, (38x80)

1

5

16cm Vaginal Retractor, (38x90)

1

6

16cm Vaginal Retractor, (38×100)

1

7

25cm Tissue Forceps, 1×2 teeth

2

8

20cm Forceps, cvd, full serrated, with teeth

2

9

25cm Uterine Dressing Forceps, double cvd

1

Lead Vest / Lead Appron

Order Detail


CODE
SCMPA 05 (Lead Vest)
SCMPA 07 (Lead Appron)
SIZE
1000 x 600 mm ; 900 x 600 mm
1000 x 600 mm ; 900 x 600 mm
MATERIAL
0.35 mmpb ; 0.50 mmpb
0.35 mmpb ; 0.50 mmpb

Circumsisi Set

Order Detail

No.Product ListEach in Package
112.5cm Dressing Forceps1
214cm Dressing Forceps1
312.5cm Mosquito Forceps, str1
412.5cm Mosquito Forceps, cvd1
5Scalpel Handle 3#1
6Needle Holders, 14cm, Crile-Wood1
7Sponge Holding Forceps, 25cm, cvd grooved, 12mm1
8Stitch Scissors, 14cm1
9Mayo Surgical Scissors,14cm str.1
10Operating Scissors,14cm straight, s-b1
1112.5cm Tissue Forceps, 1×2 teeth1
1214cm Tissue Forceps, 1×2 teeth1

Colposcope

Order Detail

Code
:
YDJ-II
Observation Angle
:
45° tilted binocular observation unit
Magnification of Eyepiece
:
16x
Focal length of Objective
:
F= 230 mm & 280 mm connecting screw: M25 x 0.75
Working Distance
:
215 mm & 260 mm
Magnification Changer
:
5 steps magnification change: 0.4x, 0.66x, 1x, 1.5x, 2.5x
Total Magnification
:
2.9x – 21.7x
Linear Field
:
11 mm – 84 mm
Beamsplitter
:
50:50 Beam splitter
Demonstrator
:
Total magnification: 2.1x – 16.4x
TV Adapter
:
C-mount 1/3″ CCD attachable
Photo Adapter
:
Optional
Illumination System
:
Coaxial illumination with cold light source fiber-optic cable, 12V 100 W halogen, brightness adjustable
Fine Focusing Distance
:
20 mm
Balanced Arm
:
Counterweight adjustable
Filter
:
Green filter with frame, to be fitted on the objective when it is used
Fiber-Optic Cable
:
130 mm
Stand
:
Short column fitted on the round base with 5 jaws and a round counterweight ring

70mA Mobile Medical X-ray Machine TNC-MX70

Order Detail

This X-ray machine features full wave rectification and modular X-ray tube head. The frame of the unit is of cantilever construction, and is compact in design and easy in movement. The machine can be used for Radiography in hospital wards or operating rooms.

Specifications
 1. Power requirements
            Voltage: 180-240V Frequency: 50Hz
     Internal resistance: ≤1Ω Rating: 5k VA
     Current: Maimum15A for radiography
        2. Time: 0.08 to 6.32 steps electronic
        3. Maximum height from X-ray tube focus to   floor>1820mm
        4. Minimum height from X-ray tube focus to floor<550mm
        5. Collimator: Maximum film size at 1000mm
            Focal distance: 430×430mm
        6. Maximum remote control distance: 6m
        7. X-ray tube focus: 2.6×2.6
        8. Unit moving force :< 5kg
        9. Net weight of the unit: 90kg

50mA Mobile Medical X-ray Machine TNC-MX50

Order Detail

This X-ray machine features full wave rectification and modular X-ray tube head. The frame of the unit, of cantilever construction, is compact in design easy of movement. The machine can be used for radiography in hospital wards or operating rooms.

Specifications
 1. Power requirements
            Voltage: 180-240V Frequency: 50Hz
            Internal resistance: ≤1ΩRating:5k VA
            Current: Maimum15A for radiography
        2. Time: 0.08 to 6.32 steps electronic
        3. Maximum height from X-ray tube focus to floor>1820mm
        4. Minimum height from X-ray tube focus to floor<550mm
        5. Collimator: Maximum film size at 1000mm Focal distance: 430×430mm
        6. Maximum remote control distance: 6m
        7. X-ray tube focus: 2.3×2.3
        8. Unit moving force: <5kg
        9. Net weight of the unit: 90kg
 
Support : Creating Website | Mas Template | Mas Template
Copyright © 2011. MEDICAL SUPPLY - All Rights Reserved
Template Created by Creating Website Published by Mas Template
Proudly powered by Blogger