Forms of Therapy:
Hemodialysis, Online Hemofiltration (Online HF), Online Hemodiafiltration
(Online HDF),Isolated Ultrafiltration, Sequential Ultrafiltration,
Hemoperfusion, Plasma exchange (optional).
Technical Features:
1. The Multi-Functional Machine Offers Customized Curing Mode For Patients.
2. The Advanced Volume Balance Control System Enables Accurate
2. The Advanced Volume Balance Control System Enables Accurate
Control of Ultrafiltration.
3. Double-Stage Intoxication Filtration Ensuring That The Substitution
3. Double-Stage Intoxication Filtration Ensuring That The Substitution
Fluid
Meets AAMI Standards.
4. Reliable System and Safe Treatment Ensured By Pressure Detectors,
4. Reliable System and Safe Treatment Ensured By Pressure Detectors,
Conductivity Detectors, Air Detectors and Blood Leakage Detectors.
Function Features:
1. Adjustable sodium And UF profiling Enable Customized Treatment For Patients.
2. Convenient Process for Sequential Ultrafiltration and Dialysis.
3. High Volume Hemofiltration (HVHF) Is Available
4. Kt/V Calculation Function Can Be Used For Evaluating the Sufficiency of Dialysis via the Urea Kinetic
Model Volume Balance System.
5. Isolated Hemoperfusion Mode, Decrease the Normal Hemodiafiltration Device Self-Detecting
5. Isolated Hemoperfusion Mode, Decrease the Normal Hemodiafiltration Device Self-Detecting
Time And The Dialysate Waste.
6. The Adaptive Regulation and Control System Effectively Avoids Various Complications.
6. The Adaptive Regulation and Control System Effectively Avoids Various Complications.
And Can Clear Middle and Small Molecules Toxin
7. Automatic Disinfestation and Decalcifilcation by Many Kinds of Disinfectant Liquids and Picking Solutions.
8. Back-Up Power Supply For 30 Min After Electricity Off.
7. Automatic Disinfestation and Decalcifilcation by Many Kinds of Disinfectant Liquids and Picking Solutions.
8. Back-Up Power Supply For 30 Min After Electricity Off.
Technical
Data:
Dimensions
(W x H x L)
|
850 ×
840×1660 MM
|
Gross
Weight
|
Aprox.
140 Kg
|
Power
Supply
|
AC220V,
50~60HZ
|
Connected
Load
|
2000VA
|
Water
Supply
|
Pressure
Range :0~8.0BAR, Temperature Range:0~35℃
|
Venous
Pressure Working Range
|
-700~+800mmhg,
Accuracy±10mmhg
|
Arterial
Pressure Working Range
|
-700~+800mmhg,
Accuracy±10mmhg
|
Transmembrane
Pressure Working Range
|
-700~+800mmhg,
Accuracy±10mmhg
|
Blood
Flow Range
|
0~700ml/Min
|
Dialysate
Flow Range
|
0~300~500~800ml/Min
(Adjustable)
|
Substitution
Fluid Flow
|
0~25L/H
|
Dialysate
Temperature Working Range
|
30~41℃,Accuracy±0.1℃
|
Heparin
Pump Working Range
|
0~10
ml/H,Accuracy±0.1ml/H
|
Conductivity
Working Range
|
10~20
ms/cm Accuracy±0.1ms/cm
|
Air
Detector
|
Detecting≥0.02ML/Single
Bubble Detecting
|
Blood
Leak Detector
|
Detecting
blood leak ≥0.35mL/min (HCT 32%)
|
Hot
Rinse
|
85℃
|
Clean/
Disinfection
|