Forms of Therapy:
Hemodialysis, Off-line Hemofiltration (Off-line HF),
Off-line Hemodiafiltration (Off-line HDF),Isolated Ultrafiltration, Sequential
Ultrafiltration, Hemoperfusion, Plasma exchange (optional).
Technical Features:
1. Multifunction, Individual Therapy.
2. The Advanced Volume Balance Control System Enables Accurate
1. Multifunction, Individual Therapy.
2. The Advanced Volume Balance Control System Enables Accurate
Control of Ultrafiltration.
3. The Diversified Treatment Modes Can Satisfy Various Clinical Needs..
4. Reliability And Safety Are Ensured By A Dual-Control-Supervising System.
3. The Diversified Treatment Modes Can Satisfy Various Clinical Needs..
4. Reliability And Safety Are Ensured By A Dual-Control-Supervising System.
Function Features:
1. Sodium And Ultrafiltration Profiles Provide Individual Treatment For
Patients.
2. Convenient Process for Sequential Ultrafiltration and Dialysis with Variational Sodium.
3. Double Pumps Design, Hemodiafiltration With Bag Can Satisfy All Kinds Of Clinical Needs.
4. KT⁄V Calculation Function Evaluates The Sufficiency Of Dialysis.
5. Automatic Disinfection and Decalcification with All Kinds of Disinfectant and Acid.
6. Convenient, Quick After-Sale Service and Low Maintenance Cost.
7. Back-Up Power Supply For 30 Min After Electricity Off.
2. Convenient Process for Sequential Ultrafiltration and Dialysis with Variational Sodium.
3. Double Pumps Design, Hemodiafiltration With Bag Can Satisfy All Kinds Of Clinical Needs.
4. KT⁄V Calculation Function Evaluates The Sufficiency Of Dialysis.
5. Automatic Disinfection and Decalcification with All Kinds of Disinfectant and Acid.
6. Convenient, Quick After-Sale Service and Low Maintenance Cost.
7. Back-Up Power Supply For 30 Min After Electricity Off.
Technical
Data:
Dimensions
(W x H x L)
|
850 × 840×1660 MM
|
Gross
Weight
|
Aprox. 140 Kg
|
Power
Supply
|
AC220V, 50~60HZ
|
Connected
Load
|
2000VA
|
Water
Supply
|
Pressure Range :0~8.0BAR, Temperature Range:0~35℃
|
Venous
Pressure Working Range
|
-700~+800mmhg, Accuracy±10mmhg
|
Arterial
Pressure Working Range
|
-700~+800mmhg, Accuracy±10mmhg
|
Transmembrane
Pressure Working Range
|
-700~+800mmhg, Accuracy±10mmhg
|
Blood
Flow Range
|
0~700ml/Min
|
Dialysate
Flow Range
|
0~300~500~800ml/Min (Adjustable)
|
Substitution
Fluid Flow
|
0~25L/H
|
Dialysate
Temperature Working Range
|
30~41℃,Accuracy±0.1℃
|
Heparin
Pump Working Range
|
0~10 ml/H,Accuracy±0.1ml/H
|
Conductivity
Working Range
|
10~20 ms/cm Accuracy±0.1ms/cm
|
Air
Detector
|
Detecting≥0.02ML/Single Bubble Detecting
|
Blood
Leak Detector
|
Detecting blood leak ≥0.35mL/min (HCT 32%)
|
Hot Rinse
|
85℃
|
Clean/
Disinfection
|
Decalcification: Rinse, citric acid
Thermal Disinfection: Hot water or citric acid Chemical Disinfection: Sodium hypochlorite or peracetic acid |