Features
1. Big screen LCD display, touch screen input, choosing to equip outlay mouse and keyboard, simple and
easy for operation.
2. The whole-new operation system, with integrated software of immunity analysis, can make direct character input of hospital management and patients’ information.
3. 8-channel optical fiber high speed scanning, special center orientation for elisa hole leads to quick and correct measuring result.
4. Single-board multi-item testing, even 12 kinds qualitative or measurable testing can be done simultaneously on the same board.
5. Double quality-control function can meet the display, storage and printing of quality-control data and chart of each item.
6. Visible and flexible board collocation, freely setting and deletion for position and quantity of blank, comparison, standard and sample
7. The instruments can intelligently judge the state of blank, comparison and standard according to the
requirement of the program parameter.
8. With the sufficient database, it can store 500 program parameters, 20000 testing results and the quality-control date and chart of more than 2 years, and call out and print out momentarily as well.
9. The CO value and standard curve of all items can be stored permanently and be called out and printed out momentarily.
10. Automatic single/double wavelength examination, support many kinds of qualitative or measurable analytical models
11. Support many kinds of built-in and outlay printers, print the whole report, program report and quality-control and patient general report.
12. With the function of all-scale query and statistics, convenient for the management of sections.
13. The intelligent resting protection function for prolonging the life-span of lamp.
14. The elisa workstation software can be chosen to equip with as well.
Main specification
1. Form of sample: 96 or 48 hole elisa board or strip.
2. Model of calculation: absorbency, cut-off qualitative calculation, single-point scaling, polyline regression, more-point percentage, linear regression, index regression, log regression, power regression, double-log regression and log-logit regression.
3. Light filter: standard configuration with 4 light filters of 405,450,492,630nm , can reach to 8 light filters ( or according to clients’ requirement)
4. Absorbance accuracy: ±0.01A
5. Absorbance repetition: ≤0.5%
6. Absorbance stability:±0.005A
7. Linear error: ±0.5%
8. Display: LCD display
9. Way of input: touch screen and pen
10. Interface: serial port RS232, parallel port (printer).
1. Form of sample: 96 or 48 hole elisa board or strip.
2. Model of calculation: absorbency, cut-off qualitative calculation, single-point scaling, polyline regression, more-point percentage, linear regression, index regression, log regression, power regression, double-log regression and log-logit regression.
3. Light filter: standard configuration with 4 light filters of 405,450,492,630nm , can reach to 8 light filters ( or according to clients’ requirement)
4. Absorbance accuracy: ±0.01A
5. Absorbance repetition: ≤0.5%
6. Absorbance stability:±0.005A
7. Linear error: ±0.5%
8. Display: LCD display
9. Way of input: touch screen and pen
10. Interface: serial port RS232, parallel port (printer).