Feature
1. Throughput: 200 test/hour
2. Test Mode:
1. Throughput: 200 test/hour
2. Test Mode:
a. End-point, Kinetics, Fixed time
b. Single and Double wavelength
c. Linearity and Non-linearity calibration
d. With and without reagent blank and(or) sample blank
e. Can use single reagent and double reagent
3. Test Range: clinical biochemistry, turbidimetry and immunoassay tests
4. Setting of test: single parameter test, multi-parameters test, combined parameters,
batch parameters test
5. Setting of parameters:
a. Completely open for editing test parameters, editing combined parameters and calculating parameters
b. Bench top compact automatic analyzer
c. Routine & STAT tests available
d. User-friendly, safe handling Liquid petro
b. Single and Double wavelength
c. Linearity and Non-linearity calibration
d. With and without reagent blank and(or) sample blank
e. Can use single reagent and double reagent
3. Test Range: clinical biochemistry, turbidimetry and immunoassay tests
4. Setting of test: single parameter test, multi-parameters test, combined parameters,
batch parameters test
5. Setting of parameters:
a. Completely open for editing test parameters, editing combined parameters and calculating parameters
b. Bench top compact automatic analyzer
c. Routine & STAT tests available
d. User-friendly, safe handling Liquid petro
Specification
1. Optical System
2. Light source: 12V/20W Halogen lamp, life span>2000h
3. Wavelength: 11 interference filters: 340, 380, 405, 450, 492, 505, 546, 578, 620, 670 and 700nm Sample System
4. Sample plate: two rotor rings, 64 positions for samples, all positions can be assigned as sample, standard,
1. Optical System
2. Light source: 12V/20W Halogen lamp, life span>2000h
3. Wavelength: 11 interference filters: 340, 380, 405, 450, 492, 505, 546, 578, 620, 670 and 700nm Sample System
4. Sample plate: two rotor rings, 64 positions for samples, all positions can be assigned as sample, standard,
quality control and blank
5. Sample volume: 5~50ul
6. Sample auto-dilution: instrument dilutes and retests the sample automatically
7. Sample needle: Auto liquid level detection function; auto-wash inner and outer wall
Reagent system
8. Sample plate: 30 reagent positions, all positions can be assigned as R1, R2
9. Reagent bottle volume: 30ml
10. Reagent refrigeration and heating: 4~10℃ Crefrigeration and reagent preheating functions
5. Sample volume: 5~50ul
6. Sample auto-dilution: instrument dilutes and retests the sample automatically
7. Sample needle: Auto liquid level detection function; auto-wash inner and outer wall
Reagent system
8. Sample plate: 30 reagent positions, all positions can be assigned as R1, R2
9. Reagent bottle volume: 30ml
10. Reagent refrigeration and heating: 4~10℃ Crefrigeration and reagent preheating functions
11. Reagent
volume: 30ml
12. Reagent needle: Auto liquid level detection function; auto-wash inner and outer wall
13. Reaction system
14. Reaction plate: turnable reaction plate, 96 disposable reaction cuvettes
15. Reaction Temperature: 37℃, temperature accuracy is ±0.1℃
16. Quality control: 3 control sera levels, calculating statistical results automatically, levey- jennings QC plot.
12. Reagent needle: Auto liquid level detection function; auto-wash inner and outer wall
13. Reaction system
14. Reaction plate: turnable reaction plate, 96 disposable reaction cuvettes
15. Reaction Temperature: 37℃, temperature accuracy is ±0.1℃
16. Quality control: 3 control sera levels, calculating statistical results automatically, levey- jennings QC plot.
Real-time inquiry the QC, print QC results
and QC plot
17. Data system
a. Computer control: Windows XP system
b. Data processing: large capacity can store test results, display, save and print reaction curve
c. Print: edit and print the completed English report, can choose and edit the printing contect,
17. Data system
a. Computer control: Windows XP system
b. Data processing: large capacity can store test results, display, save and print reaction curve
c. Print: edit and print the completed English report, can choose and edit the printing contect,
18. support the net work report printing
19. Working
environment
a. Power supply: AC220V±10%, 50Hz±2%
b. Electric power consumption: <700VA
c. Environmental Temperature: 15~32℃
d. Relative humidity: <85%
e. Water consumption: <1000ml/hour
a. Power supply: AC220V±10%, 50Hz±2%
b. Electric power consumption: <700VA
c. Environmental Temperature: 15~32℃
d. Relative humidity: <85%
e. Water consumption: <1000ml/hour
Post a Comment