TNC-2102 Anesthesia Machine




1. This machine uses in respiratory control,respiratory intensive care , 5.1 inch 
    high clear display, and real-time reflection respiratory system condition.
2. The high-precision evaporator has the stable output concentration 
    with pressure, temperature, and flow automatic compensation; 
    Choose one among Enflurane, isoflurane and sevoflurane for a matching.
3. Reliable gas Power transmission system;
4. Reasonable economic and multiple technology configuration, the user s 
    may choose flexibly;
5. Modular product design According to customer’s needs upgrade.

Main Technical Parameters
Part of Anesthesia Machine

1.      Console high-strength engineering plastic rack,light,beautiful and corrosion resistance
2.      Scope adults, children
3.      Gas source O2N2O:0.30.5MPa
4.      Flow meter O2: 0.110L/min
         N2O
: o.110L/min
5.      O2 N2O linkage and nitrous oxide Truncation device
   When use nitrous oxide, oxygen concentration>25%; when the oxygen pressure<0.2Kpa, the flow of 

    nitrous oxide would be cut off.
6.      Rapid oxygen flow 3575L/min
7.      Vaporizer
         It has the function of pressure, temperature, and flow automatic compensation. 

         The regulation range of evaporator concentration is 05vol%. Choose one among Enflurane, 
         Isoflurane and Sevoflurane for a matching according to the demands of customer.
8.      Low oxygen pressure alarm  It will be alarmed when the oxygen pressure < 0.2MPa
9.      Respiratory circuit Work mode all close. semi-close. semi-open pressure release 14KPa
10.  Bellows breathing
   Adults and children bellows tidal volume range:0
1500ml

Part of Ventilator

1.      Display mode 5.1-inch high clear display,
2.      Ventilation mode
IPPV SIPPV PLV PEEP MANU (monitor the tidal volume. ventilation. respiratory rate. ratio. peak 
pressure when use hand.)
3.      Ventilation parameters
tidal volume 50
1500ml
frequency 6
60bpm
I:E 2:1
1:4
Trigger sensitivity -1.0
-0.2Kpa
PEEP 0.2
1.0Kpa
pressure control 1
6.0Kpa
4.      Ventilation monitoring parameters
tidal volume. ventilation. IPPV ratio. total respiratory rate. breath /expiratory ratio. peak pressure . pressure control. airway pressure wave. breath pressure trigger. PEEP minimum pressure.
5.      Monitoring oxygen concentration 21%100%(choose and match)
6.      Security Alert System
Oxygen Concentration alarm (choose and match)
upper limit setting range 50%
100%
low limit setting range 15%
50%
7.      Airway pressure alarm
upper limit setting range 1.5
6.0Kpa
low limit setting range 0.2
3.0Kpa
8.      Alarm minute ventilation
upper limit setting range 2
30L/min
low limit setting range 1
12L/min
9.      Asphyxia alarm The machine will give sound and light alarm if there is no tidal volume input in 15s
Power failure alarm
10.  Power AC 220V±10% 50Hz±1Hz UPS. Battery. (choose and match).


Related product you might see:

Share this product :

Post a Comment

 
Support : Creating Website | Mas Template | Mas Template
Copyright © 2011. MEDICAL SUPPLY - All Rights Reserved
Template Created by Creating Website Published by Mas Template