Based on ergonomics of the design, structure concise and fluent, mobile, lightweight comfortable. Microcomputer control of the ventilator imported sensors and components, and production processes to ensure that rigorous internal quality products, folding bellows breathing mechanical ventilation system so that security situation, intuitive.
High-precision anesthesia evaporators to ensure that the concentration of anesthesia output accuracy. Power transmission and gas metering system to ensure the safe and reliable gas supply. The aircraft brought together a number of modern technologies, is a fine performance, functionally complete anesthesia machine.
1. This machine uses in respiratory control , respiratory intensive care , 5.7 inch high clear display, pressure-time
wave and Velocity-time wave to monitor respiratory condition Multi-directionally;
wave and Velocity-time wave to monitor respiratory condition Multi-directionally;
2. The high-precision evaporator has the stable output concentration with pressure, temperature, and
flow automatic compensation; Choose one among Enflurane, isoflurane and sevoflurane for a matching;
flow automatic compensation; Choose one among Enflurane, isoflurane and sevoflurane for a matching;
Main Technical Parameters
Part of Anesthesia Machine
1. Console
High-strength engineering plastic rack, light, beautiful and corrosion resistance
2. Scope adult, child
3. Gas source O2、N2O:0.3~0.5MPa
4. Flow meter O2: 0.1~10L/min 1.1~10L/min
N20: 0.1~10L/min 1.1~10L/min
5. O2、N2O linkage and nitrous oxide Truncation device
When use nitrous oxide, oxygen concentration>25%; when the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6. Rapid oxygen flow 35~75L/min
7. Low oxygen pressure alarm
It will be alarmed when the oxygen pressure < 0.2MPa
1. Console
High-strength engineering plastic rack, light, beautiful and corrosion resistance
2. Scope adult, child
3. Gas source O2、N2O:0.3~0.5MPa
4. Flow meter O2: 0.1~10L/min 1.1~10L/min
N20: 0.1~10L/min 1.1~10L/min
5. O2、N2O linkage and nitrous oxide Truncation device
When use nitrous oxide, oxygen concentration>25%; when the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6. Rapid oxygen flow 35~75L/min
7. Low oxygen pressure alarm
It will be alarmed when the oxygen pressure < 0.2MPa
8. Vaporizer it has
the function of pressure,
Temperature, and flow automatic compensation. The regulation range of evaporator concentration is 0~5vol%. Choose one among enflurane, isoflurane and sevoflurane for a matching according to the demands of customer.
9. Respiratory circuit
work mode all close. semi-close. semi-open
APL:0.5~7KPa
10. Bellows breathing
adults and children bellows Monitoring of humidity
volume:0~1500ml
Temperature, and flow automatic compensation. The regulation range of evaporator concentration is 0~5vol%. Choose one among enflurane, isoflurane and sevoflurane for a matching according to the demands of customer.
9. Respiratory circuit
work mode all close. semi-close. semi-open
APL:0.5~7KPa
10. Bellows breathing
adults and children bellows Monitoring of humidity
volume:0~1500ml
Part of
Ventilator
1.
Display mode
5.7-inch LCD
2.
Ventilation mode
IPPV SIPPV SIMV PEEP MANU SIGH
IPPV SIPPV SIMV PEEP MANU SIGH
3.
Ventilation
parameters
tidal volume 50~1500ml
frequency 4~60bpm
I:E 2:1~1:8
trigger sensitivity -1.0~-0.1Kpa
PEEP 0~1.0Kpa
Pressure control 1~6Kpa
SIGH 1.5 breath times
tidal volume 50~1500ml
frequency 4~60bpm
I:E 2:1~1:8
trigger sensitivity -1.0~-0.1Kpa
PEEP 0~1.0Kpa
Pressure control 1~6Kpa
SIGH 1.5 breath times
4.
Ventilation
monitoring parameters
tidal volume. ventilation. IPPV ratio. breath /expiratory ratio. peak pressure . pressure -time wave. velocity-time wave. total respiratory rate. airway pressure wave. PEEP. breath pressure trigger.
tidal volume. ventilation. IPPV ratio. breath /expiratory ratio. peak pressure . pressure -time wave. velocity-time wave. total respiratory rate. airway pressure wave. PEEP. breath pressure trigger.
5.
Monitoring oxygen
concentration 21%~100%(choose
and match)
6.
Security Alert
System
Oxygen Concentration alarm (choose and match)
upper limit setting range 50%~100%
low limit setting range 15%~50%
Airway pressure alarm
upper limit setting range 1~6Kpa
low limit setting range 0.4~2Kpa
Alarm minute ventilation
upper limit setting range 3.0~30L/min
low limit setting range 1~10L/min
Asphyxia alarm The machine will give sound and light alarm if there is no tidal volume input in 15s Power failure alarm
Oxygen Concentration alarm (choose and match)
upper limit setting range 50%~100%
low limit setting range 15%~50%
Airway pressure alarm
upper limit setting range 1~6Kpa
low limit setting range 0.4~2Kpa
Alarm minute ventilation
upper limit setting range 3.0~30L/min
low limit setting range 1~10L/min
Asphyxia alarm The machine will give sound and light alarm if there is no tidal volume input in 15s Power failure alarm
7.
Power AC 220V±10%
50Hz±1Hz
UPS. Battery. (choose and match)
UPS. Battery. (choose and match)
8.
Manipulators (choose
and match)
Post a Comment