TNC-4102 100mA MEDICAL X-RAY Machine




 Usage
 Roentgenoscopy
 Digestive track spot film photography
 General photography
 Filter-ray device photography 










Features
1. Single bed and single bulb. 
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable. 
3. The high-tension system is of march-past structure. Equipped with full-wave rectification high-voltage 
    generator and independent X-ray tube unit, this machine is with large output power and operation is reliable and stable. 
4. Supply voltage V, roentgenoscopy, photography KV and step-less adjustable. 
5. Equipped with the manostat for filament of X-ray tube and the space charge compensator as to ensure the 
    stable and accurate output. 
6. Equipped with the capacity limitation and protection circuit and KvmAS interlock limitation and protection. 
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly 
8. Examining bed is of electric back rotation and is equipped with vibrating filter-ray device. 
9. The spot film device of luminescent screen can hold the film jacket of various sizes and can make 
    the photography of full-film and two sectional films separately 
10. The upright post has the bottom track only, which is easy while installation.

Main specifications
ITEM
CONTENT
INDEX
Upright post
move lengthwise (along the bottom track)
1500mm
move transverse
360mm
move up and down (along upright post)
720-1720mm(from focus to ground)
Supply power
voltage
single phase 380V/220V
frequency
50Hz ± 0.5Hz
capacity
10KVA
inner resistance
380V:2 Ω ,220V:0.6 Ω

Max. Dc output voltage                  60KV 100KV
   Max. Dc output current                  100mA 125mA
Roentgenoscopy
voltage
                   50-90KV 500-100KV
current
0.5-5mA
Photography
voltage
50-90KV 500-100KV
current
small focus 15mA, big focus 50, 60,100mA four grades together
spot film
100mA (fixed)
time
0.04-6.3s,24 grades together
High-Voltage generator
capacity
100KVA
X-Ray tube
model
XD4-2.9/100
focus
small focus 1.8mm, big focus4.3mm
Examining Bed
rotary angle
+90°- 0°- -5°
specification of spot film(stomach and intestines photography)
128X179mm(5”X7”)
205X254mm(8”X10”)
254X305mm(10”X12”)
  MAX.CAPACITY OF PHOTOGRAY
Focus of X-ray tube
photography mA
Max. photography KV
Max. allowable expose time
small focus
25mA
90KV 100KV
1.0s
big focus
50 mA
90KV 95KV
6.3s
100 mA
85KV 90KV
2.5s
125 mA
82KV 85KV
1.0s