TNC-4105 200mA Medical X-ray Machine




 Usage
 Fluoroscopy
 Gastrointestinal radiography
 General radiography
 Ray-filter-ray radiography







Features 
1. Two tables and two tubes X-ray machine is separate and special, with fluoroscopy, gastrointestinal photography, 
    general photography, filter-ray photography.
2. Three parameters kV mA and s are sectional interlocked protection in capacity
    Both fluoroscopy and photography are equipment with limited time protection fittings.
3. Equipment with protection of the manostat for filament of X-ray tube, Space charge compensating, 
    Rotary anode starting and overrunning–temperature protection Supply power V, fluoroscopy kV, 
    photography kV and motor adjusts continuously.
4. Equipment with the electric diagnostic bed, fluorescent photography device and electromagnetism locks 
    The photography table can be used professionally, operated expediently, the ground-track is selected 
    fittings when using.

Main specifications

ITEM
CONTENT
INDEX
Outer power
Capacity
25KVA
Voltage, frequency
380V/220V±10% 50Hz±1Hz
Inner resistance
0.9Ω at 380V; 0.3Ω at 220V
Supply control
Scope
380V±10%, Be adjustable continuously or 220V±10%, Be adjustable continuously
High-voltage generator
Max-capacity
20KVA(instantaneous)
Max Dc output voltage
125KVP
Max Dc output current
200mA(instantaneous)
Fluoroscopy
Tube voltage
50-100KV electro motion be adjustable continuously
Tube current
0.5-5mA be adjustable continuously
Gastrointestinal radiography
Tube voltage
50-110KVP
Tube current
150mA(fixed)
Fluoroscopy Gastrointestinal radiography X-Ray tube
Focus
Small: 1×1mm  big: 2×2mm
Model
XD51-2040/125
General radiographyfilter-ray radiography
Tube voltage
50~125KVP
Tube current
Small focus: 50,100mA
big focus:50,100,150,200mA
Radiography X-Ray tube
Focus
Small focus:1×1mm big focus: 2×2mm
Model
XD51-20,40/125
Diagnostic bed
Rotary scope
90°-0°--10°
Bed L×W×H
1960×702×820mm
Fluoroscopy Gastrointestinal radiography equipment
Horizontal
About ±90mm
Up and down
580mm
Lock mode
Electromagnetism lock
Light control
manual,single-vane beam limiting device
Photograph specification
128×179mm(5”×7”)  in two
205×254mm(8”×10”)  in two
254×305mm(10”×12”)  in two
279×355mm(11”×14”)  in four
Radiography bed
 (mm) L×W×H
2000×710×700mm
Lengthwise
700mm
Vibration Ray-filter device
Lengthwise distance550mm
Grid density N28
grid ratio r8
Convergence distance f0100cm
X-Ray tube unit-support
Lengthwise
2100mm
Up and down
325-1825mm
Tube turning around the shaft of arm
180°
Turning around the shaft of tube
-10°-90°-120°










Related product you might see:

Share this product :

Post a Comment

 
Support : Creating Website | Mas Template | Mas Template
Copyright © 2011. MEDICAL SUPPLY - All Rights Reserved
Template Created by Creating Website Published by Mas Template
Proudly powered by Blogger