Usage
Fluoroscopy
Gastrointestinal radiography
General radiography
Ray-filter-ray radiography
Gastrointestinal radiography
General radiography
Ray-filter-ray radiography
Features
1. Two tables and two tubes X-ray machine is separate and
special, with fluoroscopy, gastrointestinal photography,
general photography,
filter-ray photography.
2. Three parameters kV mA and s are sectional interlocked
protection in capacity
Both fluoroscopy and photography are equipment
with limited time protection fittings.
3. Equipment with protection of the manostat for filament of
X-ray tube, Space charge compensating,
Rotary anode starting and
overrunning–temperature protection Supply power V, fluoroscopy kV,
photography kV
and motor adjusts continuously.
4. Equipment with the electric diagnostic bed, fluorescent
photography device and electromagnetism locks
The photography table can be used
professionally, operated expediently, the ground-track is selected
fittings
when using.
Main
specifications
ITEM
|
CONTENT
|
INDEX
|
Outer
power
|
Capacity
|
25KVA
|
Voltage,
frequency
|
380V/220V±10%
50Hz±1Hz
|
|
Inner
resistance
|
0.9Ω
at 380V; 0.3Ω at 220V
|
|
Supply
control
|
Scope
|
380V±10%,
Be adjustable continuously or 220V±10%, Be adjustable continuously
|
High-voltage
generator
|
Max-capacity
|
20KVA(instantaneous)
|
Max
Dc output voltage
|
125KVP
|
|
Max
Dc output current
|
200mA(instantaneous)
|
|
Fluoroscopy
|
Tube
voltage
|
50-100KV
electro motion be adjustable continuously
|
Tube
current
|
0.5-5mA
be adjustable continuously
|
|
Gastrointestinal
radiography
|
Tube
voltage
|
50-110KVP
|
Tube
current
|
150mA(fixed)
|
|
Fluoroscopy
Gastrointestinal radiography X-Ray tube
|
Focus
|
Small:
1×1mm big: 2×2mm
|
Model
|
XD51-20、40/125
|
|
General
radiography、filter-ray radiography
|
Tube
voltage
|
50~125KVP
|
Tube
current
|
Small
focus: 50,100mA
big focus:50,100,150,200mA |
|
Radiography
X-Ray tube
|
Focus
|
Small
focus:1×1mm big focus: 2×2mm
|
Model
|
XD51-20,40/125
|
|
Diagnostic
bed
|
Rotary
scope
|
90°-0°--10°
|
Bed
L×W×H
|
1960×702×820mm
|
|
Fluoroscopy
Gastrointestinal radiography equipment
|
Horizontal
|
About
±90mm
|
Up
and down
|
580mm
|
|
Lock
mode
|
Electromagnetism
lock
|
|
Light
control
|
manual,single-vane
beam limiting device
|
|
Photograph
specification
|
128×179mm(5”×7”)
in two
|
|
205×254mm(8”×10”)
in two
|
||
254×305mm(10”×12”)
in two
|
||
279×355mm(11”×14”)
in four
|
||
Radiography
bed
|
(mm)
L×W×H
|
2000×710×700mm
|
Lengthwise
|
700mm
|
|
Vibration
Ray-filter device
|
Lengthwise
distance》550mm
|
|
Grid
density N28
|
||
grid
ratio r8
|
||
Convergence
distance f0100cm
|
||
X-Ray
tube unit-support
|
Lengthwise
|
2100mm
|
Up
and down
|
325-1825mm
|
|
Tube
turning around the shaft of arm
|
180°
|
|
Turning
around the shaft of tube
|
-10°-90°-120°
|
Post a Comment