TNC-4104 200mA Medical X-ray Camera

Order Detail





UsageGeneral Photograph & Ray-filter Photograph










Features            
1. Single bed and single bulb 
2. Design according to the electric mechanism of middle-size machine.The function is full and reasonable. 
3. The high-tension system is of march-past structure. Equipped with full-wave rectification high-voltage generator and
    independent X-ray tube unit, this machine is with large output power and operation is reliable and stable. 
4. Supply voltage V, roentgenoscopy, photography KV and step-less adjustable. 
5. Equipped with the manostat for filament of X-ray tube and the space-charge compensator as to ensure the 
    stable and accurate output. 
6. Equipped with the capacity limitation and protection circuit and KvmAS interlock limitation and protection. 
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly 
8. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power. 
9. Photographic bed can move in length and breadth 
10. The photographic bed, pillar and vibrating ray-filter are in a whole without top and bottom track.

Main specifications 
Supply power
capacity
Two-phase 30KVA
voltage frequency
380V/220V ± 10% 50Hz ± 0.5Hz
inner resistance
0.75 Ω at 380V, 0.25 Ω at 220V
Power supply
Adjustable range
380V,380V ± 10% ,220V ,220V ± 10%being adjustable continuously
Photography
voltage
50-125KV, be adjustable continuously
current
small focus 50mA 100mA , big focus 50,100,200, 300mA
time
0.04-6.3s, 23 grades together according to R10 coefficient
High-Voltage generator
capacity
20KVA(instantaneous)
Max. Dc output voltage
125KV
Max. Dc output current
300mA
X-Ray tube
model
XD51-2040/125
focus
small focus 1X1mm big focus 2X2mm
Photographic bed(YZ-I)
Bed face(LXWXH)
2000mmX665X700mm
Moving range of bed face
640mm in length, 200mm in breadth
Ray-filter of bed
Travel in length >=500mm
Grid density N28
Convergence distance fo 100cm
Grid ratio R8
Pillar of X-ray source unit
Moving in length along photographic bed
1800mm or 1600mm
Distance around as moving up and down(along upright post)
650-1800mm
Rotary around the center of cross arm
± 180°
Rotary around the shaft line of X-ray annular tubes
-10 °- 60°- +120°
Max size of cassette for photograph
356mmX432mm(14”X17”)

TNC-4105 200mA Medical X-ray Machine

Order Detail



 Usage
 Fluoroscopy
 Gastrointestinal radiography
 General radiography
 Ray-filter-ray radiography







Features 
1. Two tables and two tubes X-ray machine is separate and special, with fluoroscopy, gastrointestinal photography, 
    general photography, filter-ray photography.
2. Three parameters kV mA and s are sectional interlocked protection in capacity
    Both fluoroscopy and photography are equipment with limited time protection fittings.
3. Equipment with protection of the manostat for filament of X-ray tube, Space charge compensating, 
    Rotary anode starting and overrunning–temperature protection Supply power V, fluoroscopy kV, 
    photography kV and motor adjusts continuously.
4. Equipment with the electric diagnostic bed, fluorescent photography device and electromagnetism locks 
    The photography table can be used professionally, operated expediently, the ground-track is selected 
    fittings when using.

Main specifications

ITEM
CONTENT
INDEX
Outer power
Capacity
25KVA
Voltage, frequency
380V/220V±10% 50Hz±1Hz
Inner resistance
0.9Ω at 380V; 0.3Ω at 220V
Supply control
Scope
380V±10%, Be adjustable continuously or 220V±10%, Be adjustable continuously
High-voltage generator
Max-capacity
20KVA(instantaneous)
Max Dc output voltage
125KVP
Max Dc output current
200mA(instantaneous)
Fluoroscopy
Tube voltage
50-100KV electro motion be adjustable continuously
Tube current
0.5-5mA be adjustable continuously
Gastrointestinal radiography
Tube voltage
50-110KVP
Tube current
150mA(fixed)
Fluoroscopy Gastrointestinal radiography X-Ray tube
Focus
Small: 1×1mm  big: 2×2mm
Model
XD51-2040/125
General radiographyfilter-ray radiography
Tube voltage
50~125KVP
Tube current
Small focus: 50,100mA
big focus:50,100,150,200mA
Radiography X-Ray tube
Focus
Small focus:1×1mm big focus: 2×2mm
Model
XD51-20,40/125
Diagnostic bed
Rotary scope
90°-0°--10°
Bed L×W×H
1960×702×820mm
Fluoroscopy Gastrointestinal radiography equipment
Horizontal
About ±90mm
Up and down
580mm
Lock mode
Electromagnetism lock
Light control
manual,single-vane beam limiting device
Photograph specification
128×179mm(5”×7”)  in two
205×254mm(8”×10”)  in two
254×305mm(10”×12”)  in two
279×355mm(11”×14”)  in four
Radiography bed
 (mm) L×W×H
2000×710×700mm
Lengthwise
700mm
Vibration Ray-filter device
Lengthwise distance550mm
Grid density N28
grid ratio r8
Convergence distance f0100cm
X-Ray tube unit-support
Lengthwise
2100mm
Up and down
325-1825mm
Tube turning around the shaft of arm
180°
Turning around the shaft of tube
-10°-90°-120°










TNC-4106 300mA Medical X-ray Camera

Order Detail





Usage : General Photograph Ray-filter Photograph











Features 
1. Single bed and single bulb 
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable. 
3. The high-tension system is of march-past structure. Equipped with full-wave rectification high-voltage generator and
    independent X-ray tube unit, this machine is with large output power and operation is reliable and stable. 
4. Supply voltage V, roentgenoscopy, photography KV and step-less adjustable. 
5. Equipped with the manostat for filament of X-ray tube and the space-charge compensator as to ensure
    the stable and accurate output. 
6. Equipped with the capacity limitation and protection circuit and KvmAS interlock limitation and protection. 
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly 
8. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power. 
9. Photographic bed can move in length and breadth 
10. The photographic bed, pillar and vibrating ray-filter are in a whole without top and bottom track.

Main specifications
ITEM
CONTENT
INDEX
Supply power
capacity
Two-phase 30KVA
voltage frequency
380V/220V ± 10% 50Hz ± 0.5Hz
inner resistance
0.75 Ω at 380V, 0.25 Ω at 220V
Power supply
Adjustable range
380V,380V ± 10% ,220V ,220V ± 10%being adjustable continuously
Photography
voltage
50-125KV Be adjustable continuously
current
small focus 50mA 100mA, big focus 50,100,200, 300mA
time
0.04-6.3s,23 grades together according to R10 coefficient
High-Voltage generator
capacity
20KVA(instantaneous)
Max. Dc output voltage
125KV
Max. Dc output current
300mA
X-Ray tube
model
XD51-2040/125
focus
small focus 1X1mm big focus 2X2mm
Photographic bed(YZ-I)
Bed face(LXWXH)
2000X665X700mm
Moving range of bed face
640mm in length, 200mm in breadth
Ray-filter of bed
Travel in length >=500mm
Grid density N28
Convergence distance fo 100cm
Grid ratio R8
Pillar of X-ray source unit
Moving in length along photographic bed
1800mm or 1600mm
Distance around as moving up and down(along upright post)
650-1800mm
Rotary around the center of cross arm
± 180°
Rotary around the shaft line of X-ray annular tubes
-10 ° - 60° - +120°
Max size of cassette for photograph
356mmX432mm(14”X17”)
 